Datasheet

±
3.3V Electrical Characteristics (Continued)
V
S
=
±
3.3V, R
L
= 100; Unless otherwise specified.
Symbol Parameter Conditions(Note 2) Min Typ Max Units
HD3 3
rd
Harmonic Distortion 2 V
PP
, 10MHz −74 dBc
IMD 3
rd
Order Intermodulation Products 10 MHz, Two tones 2Vpp at output −79 dBc
Static, DC Performance
GAIN Voltage Gain 2.0 V/V
VIO Output Offset Voltage V
IN
=0V 1 mV
DVIO Average Drift 36 µV/˚C
IBN Input Bias Current (Note 7) V
IN
=0V 2 µA
DIBN Average Drift 24 nA/˚C
PSRR Power Supply Rejection Ratio DC, Input Referred 54 dB
ICC Supply Current R
L
=
20 mA
VIH Logic High Threshold Select & Enable Pins 1.3 V
VIL Logic Low Threshold Select & Enable Pins 0.4 V
Miscellaneous Performance
RIN+ Input Resistance 100 k
CIN Input Capacitance 0.9 pF
ROUT Output Resistance 0.27
VO Output Voltage Range No Load
±
2.5 V
VOL R
L
= 100
±
2.2 V
CMIR Input Voltage Range
±
1.2 V
IO Linear Output Current V
IN
=0V
±
60 mA
ISC Short Circuit Current V
IN
=
±
1V, Output shorted to
ground
±
150 mA
XTLK Channel to Channel Crosstalk 5 MHz −90 dBc
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
intended to be functional, but specific performance is not guaranteed. For guaranteed specifications, see the Electrical Characteristics tables.
Note 2: Electrical Table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very limited self-heating of
the device such that T
J
=T
A
. No guarantee of parametric performance is indicated in the electrical tables under conditions of internal self heating where T
J
>
T
A
.
See Applications Section for information on temperature de-rating of this device. Min/Max ratings are based on product testing, characterization and simulation.
Individual parameters are tested as noted.
Note 3: The maximum output current (I
OUT
) is determined by device power dissipation limitations. See the Power Dissipation section of the Application Section for
more details. A short circuit condition should be limited to 5 seconds or less.
Note 4: Human Body model, 1.5 k in series with 100 pF. Machine model, 0 In series with 200 pF
Note 5: Parameters guaranteed by electrical testing at 25˚ C.
Note 6: Parameters guaranteed by design.
Note 7: Positive Value is current into device.
LMH6572