Datasheet

LMH6553
www.ti.com
SNOSB07H SEPTEMBER 2008REVISED MARCH 2013
V
S
= ±2.5V Electrical Characteristics
(1)
(continued)
Unless otherwise specified, all limits are ensured for T
A
= 25°C, V
S
= ±2.5V, A
V
= 1, V
CM
= 0V, V
CLAMP
= 2V, R
F
= R
G
= 275,
R
L
= 200, for single-ended in, differential out. Boldface limits apply at the temperature extremes.
Symbol Parameter Conditions Min
(2)
Typ
(3)
Max
(2)
Units
Clamp Overshoot V
IN
= 1V Step, A
V
= 2 V/V, V
CLAMP
= 0.5V, 105 mV
V
CM
= 0V, 100% Overdrive
Clamp Overshoot V
IN
= 1V Step, A
V
= 2 V/V, V
CLAMP
= 1V, 105 mV
V
CM
= 0.5V, 100% Overdrive
Clamp Overshoot Width
(9)
650 ps
Clamp Overdrive Recovery Time V
IN
= 2V Step, A
V
= 2 V/V, V
CLAMP
= 0.5V, 600 ps
V
CM
= 0V, 50% Output Crossing
Linearity Guardband
(10)
f = 75 MHz, V
OD
= 2 V
PP
, R
L
= 800, SFDR 40 mV
Down 3 dB
Output Common Mode Control Circuit
Common Mode Small Signal V
IN
+
= V
IN
= 0 130 MHz
Bandwidth
Slew Rate V
IN
+
= V
IN
= 0 186 V/μs
V
OSCM
Output Common Mode Error Common Mode, V
IN
= float, V
CM
= 0 20 2 20 mV
Input Bias Current V
CM
= 0,
(11)
3.5 µA
Voltage Range ±0.75 ±0.81 V
CMRR Measure V
OD
, V
ID
= 0V 84 dB
Input Resistance 200 k
Gain ΔV
O,CM
/ΔV
CM
0.995 1.00 1.008 V/V
Miscellaneous Performance
Z
T
Open Loop Transimpedance Differential 105 dB
PSRR Power Supply Rejection Ratio DC, ΔV
S
= ±1V 85 dB
I
S
Supply Current R
L
= 23 26.5 30
mA
34
(9) Clamp Overshoot Width is the duration of overshoot in a 100% overdrive condition.
(10) Linearity Guardband is defined for an output sinusoid (f = 75 MHz, V
OD
= 2 V
PP
). It is the difference between the V
CLAMP
level and the
peak output voltage where the SFDR is decreased by 3 dB.
(11) Negative current implies current flowing out of the device.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LMH6553