APPLICATION INFORMATION
FUNCTIONAL OVERVIEW
The LMH1983 is an analog phase locked loop (PLL) clock generator that can output simultaneous clocks at any
of a variety of video and audio rates, synchronized or “genlocked” to H sync and V sync input reference timing.
The LMH1983 features an output Top of Frame (TOF) pulse generator for each of its four channels, each with
programmable timing that can also be synchronized to the reference frame. The clock generator uses a two-
stage PLL architecture. The first stage is a VCXO-based PLL (PLL1) that requires an external 27 MHz VCXO
and loop filter. In Genlock mode, PLL1 can phase lock the VCXO clock to the input reference. The use of a
VCXO provides a low phase noise clock source even when the LMH1983 is configured with a low loop
bandwidth, which is necessary to attenuate input timing jitter for minimum jitter transfer. The combination of the
external VCXO, external loop filter, and programmable PLL parameters can provide flexibility for the system
designer to optimize the loop bandwidth and loop response for the application.
Depending on mode, the second stage consists of three PLLs (PLL2, PLL3, PLL4) with integrated VCOs and
loop filters. These PLLs continually track the reference VCXO clock phase from PLL1 regardless of the device
mode. The PLL2 and PLL3 have pre-configured divider ratios to provide frequency multiplication or translation
from the VCXO clock frequency to generate the two common HD clock rates (148.5 MHz and 148.35 MHz).
PLL4 is pre-configured to generate an audio clock which defaults to a 24.576 MHz output, although PLL4 has
several registers which allow it to be re-configured for a variety of applications.
The VCO PLLs use a high loop bandwidth to assure PLL stability, so the VCXO must provide a stable low-jitter
clock reference to ensure optimal output jitter performance. Any unused clock or TOF output can be put in Hi-Z
mode, which can be useful for reducing power dissipation as well as reducing jitter or phase noise on the active
clock output. The TOF pulse can be programmed to indicate the start (top) of frame and even provide format
cross-locking. The output format registers should be programmed to specify the output timing (output clocks and
TOF pulse), the output timing offset relative to the reference, and the output initialization (alignment) to the
reference frame. If unused, the TOF output can also be put in Hi-Z mode.
When a loss of reference occurs during genlock, PLL1 can default to either Free-run or Holdover operation.
When Free-run is selected, the output frequency accuracy will be determined by the external bias on the free-run
control voltage input pin, VC_FREE-RUN. When Holdover is selected, the loop filter can hold the control voltage
to maintain short-term output phase accuracy for a brief period in order to allow the application to select the
secondary input reference and re-lock the outputs. These options in combination with proper PLL1 loop response
design can provide flexibility to manage output clock behavior during loss and re-acquisition of the reference. The
reference status and PLL lock status flags can provide real-time status indication to the application system. The
loss of reference and lock detection thresholds can also be configured.
I
2
C INTERFACE PROTOCOL
The protocol of the I
2
C interface begins with the start pulse, followed by a byte which consists of a seven-bit
slave device address and a Read/Write bit as an LSB. The default address of the LMH1983 for write sequences
is CCh (11001100) and for read addresses is CDh (11001101). The base address can be changed with the
ADDR pin with ADDR Open, the base address is 66h (which when left shifted becomes the CCh address),
with ADDR connected to GND, the base address is 65h, and with ADDR connected to V
DD
, the base address is
67h.
WRITE SEQUENCE
The write sequence begins with a start condition, which consists of the master pulling SDA low, while SCL is
high, next the slave address is sent, the address is made up of the 7 bit address, followed by the read/write bit,
which for a write is (0). For the default base address of 66h, (1100110), the 0 is appended to the end, and the
net address is CCh. Each byte sent after the address is followed by an ACK bit. When SCK is high, the master
will release the SDA line, the slave pulls SDA low to acknowledge. Once the device address has been sent, the
next byte sent is the register address following the register address and the ACK, the data byte is sent. When
more than one data byte is sent, the address is automatically incremented so that the data is written into the next
address location. Note in the Write Sequence Timing diagram that there is an ACK bit following each data byte.