Datasheet
LMH0356
www.ti.com
SNLS270K –AUGUST 2007–REVISED APRIL 2013
Differential output SCO/SDO2 functions as the second serial data output when the SCO_EN input is a logic-low
level. This output functions as the serial clock output when the SCO_EN input is a logic-high level. The SCO_EN
input has an internal pull-down device and the default state of SCO_EN is low (serial data output 2 enabled).
SCO/SDO2 is muted when the OUTPUT MUTE input is a logic low level. When the Bypass mode is activated
and this output is functioning as a serial clock output, the output will also be muted. If an unsupported data rate is
used while in Auto Bypass mode with this output functioning as a serial clock output, the output is invalid.
Control Inputs and Indicator Outputs
SERIAL DATA RATE SELECTOR
The Serial Data Rate Selector (RATE [1:0]) permits the user to fix the operating serial data rate. The pins have
internal pull-downs which maintain a logic-low input condition unless externally driven to a logic-high condition.
This input also serves to place the device in a test mode. The codes shown in Table 1 select the desired
operating serial data rate. The LMH0356 then enters either the Auto-Rate Detect mode or a single operating rate.
Selecting the 270 Mbps rate mode may also be used when reclocking DVB-ASI data. DVB-ASI data is MPEG2
coded data that is transmitted in 8B10B coding. The device will reclock this data without harmonic locking.
Table 1. Data Rate Select Input Codes
RATE [1:0] Data Rate or Mode
Comments
Code
00 Auto-Rate Detect mode
01 270 Mbps May be used to support DVB-ASI operation
10 1483/1485 Mbps, 2967/2970 Mbps
SERIAL DATA INPUT SELECTOR
The Serial Data Input Selector (SEL [1:0]) allows the user to select the active input channel. Table 2 shows the
input selected for a given state of SEL [1:0]. The SEL pins have internal pull-downs.
Table 2. Data Input Select Codes
SEL [1:0] Code Selected Input
00 SDI0
01 SDI1
10 SDI2
11 SDI3
LOCK DETECT
The Lock Detect output, when high, indicates that data is being received and the PLL is locked. Lock Detect may
be connected to the OUTPUT MUTE input to mute the data and clock outputs when no data signal is being
received. Note that when the Bypass/Auto Bypass input is set high, Lock Detect will remain low. See Table 3.
OUTPUT MUTE
The OUTPUT MUTE input, when low, mutes the serial data and clock outputs. It may be connected to Lock
Detect or externally driven to mute or un-mute the outputs. If OUTPUT MUTE is connected to Lock Detect, then
the data and clock outputs are muted when the PLL is not locked. This function overrides the Bypass function:
see Table 3. OUTPUT MUTE has an internal pull-up device to enable the output by default.
BYPASS/AUTO BYPASS
The Bypass/Auto Bypass input, when high, forces the device to output the data without reclocking it. When this
input is low, the device automatically bypasses the reclocking function when the device is in an unlocked
condition or the detected data rate is a rate which the device does not support. Note that when the Bypass/Auto
Bypass input is set high, Lock Detect will remain low. See Table 3. BYPASS/AUTO BYPASS has an internal pull-
down device.
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Links: LMH0356