Datasheet
LMH0307
www.ti.com
SNLS286I –APRIL 2008–REVISED APRIL 2013
READING A REGISTER
To read a register, the following protocol is used (see SMBus 2.0 specification).
1. The Host drives a START condition, the 7-bit SMBus address, and a “0” indicating a WRITE.
2. The Device (Slave) drives the ACK bit (“0”).
3. The Host drives the 8-bit Register Address.
4. The Device drives an ACK bit (“0”).
5. The Host drives a START condition.
6. The Host drives the 7-bit SMBus Address, and a “1” indicating a READ.
7. The Device drives an ACK bit “0”.
8. The Device drives the 8-bit data value (register contents).
9. The Host drives a NACK bit “1”indicating end of the READ transfer.
10. The Host drives a STOP condition.
Copyright © 2008–2013, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Links: LMH0307