Datasheet
SUPPLY CURRENT (mA)
75
55
BELDEN 1694A CABLE LENGTH (m)
0 400200
100 300
60
65
70
LMH0074
www.ti.com
SNLS277D –AUGUST 2007–REVISED APRIL 2013
APPLICATION INFORMATION
PCB LAYOUT RECOMMENDATIONS
Refer to the following Application Note on TI's website: AN-1372, “LMH0034 PCB Layout Techniques.” The PCB
layout techniques in the application note apply to the LMH0074 as well.
SUPPLY CURRENT VS. CABLE LENGTH
The supply current (I
CC
) depends on the amount of cable being equalized. The current is highest for short cable
and decreases as the cable length is increased. Figure 2 shows supply current vs. Belden 1694A cable length for
270 Mbps data.
Figure 2. Supply Current vs. Belden 1694A Cable Length, 270 Mbps
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LMH0074