Datasheet

LME49713
www.ti.com
SNAS386F SEPTEMBER 2007REVISED MARCH 2013
ABSOLUTE MAXIMUM RATINGS
(1)(2)(3)
Power Supply Voltage (V
S
= V
+
- V
-
) 38V
Storage Temperature 65°C to 150°C
Input Voltage (V-) - 0.7V to (V+) + 0.7V
Output Short Circuit
(4)
Continuous
Power Dissipation Internally Limited
ESD Rating
(5)
2000V
ESD Rating
(6)
200V
Junction Temperature 150°C
Thermal Resistance
θ
JA
(MA) 145°C/W
Temperature Range
T
MIN
T
A
T
MAX
–40°C T
J
70°C
Supply Voltage Range ±5.0V V
S
± 18V
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied. The Recommended Operating
Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions. All
voltages are measured with respect to the ground pin, unless otherwise specified.
(2) The Electrical Characteristics tables list ensured specifications under the listed Recommended Operating Conditions except as
otherwise modified or specified by the Electrical Characteristics Conditions and/or Notes. Typical specifications are estimations only and
are not ensured.
(3) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(4) Amplifier output connected to GND, any number of amplifiers within a package.
(5) Human body model, applicable std. JESD22-A114C.
(6) Machine model, applicable std. JESD22-A115-A.
Copyright © 2007–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LME49713