Bit Name Read/Write Description
4-7 Temp [3:0] Read/Write The lower nibble (4 LSbs) of the 11-bit plus sign temperature data:
<4> = Temp [0] (nibble LSb, 0.0625°C),
<5> = Temp [1],
<6> = Temp [2],
<7> = Temp [3] (nibble MSb, 0.5°C).
For 8-bit plus sign temperature resolution:
<7> = Temp [0] (LSb, 0.5°C)
<4:6> are undefined
Conversion Rate Register—Address 07h
Power on default <7:0> = 0000 0000 binary
Bit Name Read/Write Description
0 CR1 Read/Write Controls conversion rate:
0 = 728ms (typical)
1 = Continuous Conversion.
Note:
— Each voltage channel conversion takes 3 ms typical.
— Temperature conversion takes 3.6 ms typical for 9 - bit resolution and 23.5 ms typical for 12
- bit resolution.
— Each fan tachometer input is monitored for 2 pulses, the time interval for two pulses is added
to the round robin time for each fan tach input that is enabled.
1-7 Reserved Read only Reserved — will always report zero.
Voltage/Temperature Channel Disable Register—Address 08h
Power on default <7:0> = 0000 0000 binary
Bit Name Read/Write Description
0 IN0 Read/Write When set to "1", IN0:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
1 IN1 Read/Write When set to "1", IN1:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
2 IN2 Read/Write When set to "1", IN2:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
3 IN3 Read/Write When set to "1", IN3:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
4 IN4 Read/Write When set to "1", IN4:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
5 IN5 Read/Write When set to "1", IN5:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
6 IN6 Read/Write When set to "1", IN6:
conversions are skipped and disabled
value register reading will be 0
error events will be suppressed
7 Temp Read/Write When set to "1", Temperature:
conversions are skipped and disabled
value register readings will be 0
error events will be suppressed
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 27