Datasheet
LM96080
SNAS465D –SEPTEMBER 2009–REVISED MARCH 2013
www.ti.com
Temperature Data Format
Temperature data can be read from the Temperature Reading Register (address 27h). Temperature limits can be
read from and written to the Hot Temperature, Hot Temperature Hysteresis, OS Temperature, and OS
Temperature Hysteresis Limit Registers (addresses 38h - 3Bh). These limits are also referred to as T
hot
, T
hot hyst
,
T
os
, and T
os hyst
respectively. Each limit is represented by an 8-bit, two's complement word with an LSb (Least
Significant Bit) equal to 1°C:
Temperature Digital Output
Binary Hex
+125°C 0111 1101 7Dh
+25°C 0001 1001 19h
+1.0°C 0000 0001 01h
+0°C 0000 0000 00h
−1.0°C 1111 1111 FFh
−25°C 1110 0111 E7h
−55°C 1100 1001 C9h
By default, Temperature Reading Register is represented by a 9-bit two's complement digital word with the LSb
having a resolution of 0.5°C:
Temperature Digital Output
Binary Hex
+125°C 0 1111 1010 0 FAh
+25°C 0 0011 0010 0 32h
+1.5°C 0 0000 0011 0 03h
+0°C 0 0000 0000 0 00h
−0.5°C 1 1111 1111 1 FFh
−25°C 1 1100 1110 1 CEh
−55°C 1 1001 0010 1 92h
Temperature Register data can also be represented by a 12-bit two's complement digital word with a LSb of
0.0625°C:
Temperature Digital Output
Binary Hex
+125°C 0111 1101 0000 7 D0h
+25°C 0001 1001 0000 1 90h
+1.0°C 0000 0001 0000 0 10h
+0.0625°C 0000 0000 0001 0 01h
0°C 0000 0000 0000 0 00h
(−0.0625)°C 1111 1111 1111 F FFh
(−1.0)°C 1111 1111 0000 F F0h
(−25)°C 1110 0111 0000 E 70h
(−55)°C 1100 1001 0000 C 90h
20 Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: LM96080