Datasheet

LM95245
SNIS148G OCTOBER 2007REVISED MARCH 2013
www.ti.com
STATUS REGISTERS
Table 23. Status Register 1
(Read Only Address 02h):
D7 D6 D5 D4 D3 D2 D1 D0
Busy 0 0 ROS 0 Diode Fault RTCRIT LOC
Bits Name Description
7 Busy When set to "1" the part is converting.
6-5 Reserved Report "0" when read.
4 ROS Status Bit for Remote OS
3 Reserved Reports "0" when read.
2 Status bit for missing diode (Either D+ is shorted to GND, or V
DD
; or D+ is floating.)
Diode Fault Note: The unsigned registers will report 0°C if read; the signed value registers will report
128.000°C.
1 RTCRIT Status bit for Remote TCRIT.
0 LOC Status bit for the shared Local OS and TCRIT .
Table 24. Status Register 2
(Read Only Address 33h):
D7 D6 D5 D4 D3 D2 D1 D0
Not Ready Reserved 0 0 0 0 0 0
Bits Name Description
7 Not Ready Waiting for 30 ms power-up sequence to end.
6 Reserved Can report "0" or "1" when read.
5-0 Reserved Reports "0" when read.
LIMIT REGISTERS
Table 25. Unsigned Remote OS Limit - 0°C to 255°C
(Read/Write Address 07h/0Dh or 0Dh/07h):
D7 D6 D5 D4 D3 D2 D1 D0
128 64 32 16 8 4 2 1
Power on Reset default is 55h (85°C).
Table 26. Unsigned Local Shared OS and T_CRIT Limit - 0°C to 127°C
(Read/Write Address 20h):
D7 D6 D5 D4 D3 D2 D1 D0
128 64 32 16 8 4 2 1
Power on Reset default is 55h (85°C).
Table 27. Unsigned Remote T_CRIT Limit - 0°C to 255°C
(Read/Write Address 19h):
D7 D6 D5 D4 D3 D2 D1 D0
128 64 32 16 8 4 2 1
Power on Reset default is 6Eh (110°C).
22 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: LM95245