Datasheet
LM95241
SNIS143E –AUGUST 2006–REVISED MARCH 2013
www.ti.com
Logic Electrical Characteristics Digital DC Characteristics
Unless otherwise noted, these specifications apply for V
DD
=+3.0 to 3.6 Vdc. Boldface limits apply for T
A
= T
J
= T
MIN
to
T
MAX
; all other limits T
A
= T
J
=+25°C, unless otherwise noted.
Symbol Parameter Conditions Typical
(1)
Limits
(2)
Units
(Limit)
SMBDAT, SMBCLK INPUTS
V
IN(1)
Logical “1” Input Voltage 2.1 V (min)
V
IN(0)
Logical “0”Input Voltage 0.8 V (max)
V
IN(HYST)
SMBDAT and SMBCLK Digital Input 400 mV
Hysteresis
I
IN(1)
Logical “1” Input Current V
IN
= V
DD
0.005 ±10 µA (max)
I
IN(0)
Logical “0” Input Current V
IN
= 0 V −0.005 ±10 µA (max)
C
IN
Input Capacitance 5 pF
SMBDAT OUTPUT
I
OH
High Level Output Current V
OH
= V
DD
10 µA (max)
V
OL
SMBus Low Level Output Voltage I
OL
= 4mA 0.4 V (max)
I
OL
= 6mA 0.6
(1) Typical figures are at T
A
= 25°C and represent most likely parametric norms at the time of product characterization. The typical
specifications are not ensured.
(2) Limits are specified to Texas Instruments' AOQL (Average Outgoing Quality Level).
Logic Electrical Characteristics SMBus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for V
DD
=+3.0 Vdc to +3.6 Vdc, C
L
(load capacitance) on output lines = 80
pF. Boldface limits apply for T
A
= T
J
= T
MIN
to T
MAX
; all other limits T
A
= T
J
= +25°C, unless otherwise noted.
The switching characteristics of the LM95241 fully meet or exceed the published specifications of the SMBus version 2.0. The
following parameters are the timing relationships between SMBCLK and SMBDAT signals related to the LM95241. They
adhere to but are not necessarily the SMBus bus specifications.
Symbol Parameter Conditions Typical
(1)
Limits
(2)
Units
(Limit)
f
SMB
SMBus Clock Frequency 100 kHz (max)
10 kHz (min)
t
LOW
SMBus Clock Low Time from V
IN(0)
max to V
IN(0)
max 4.7 µs (min)
25 ms (max)
t
HIGH
SMBus Clock High Time from V
IN(1)
min to V
IN(1)
min 4.0 µs (min)
t
R,SMB
SMBus Rise Time See
(3)
1 µs (max)
t
F,SMB
SMBus Fall Time See
(4)
0.3 µs (max)
t
OF
Output Fall Time C
L
= 400pF, 250 ns (max)
I
O
= 3mA
(4)
t
TIMEOUT
SMBDAT and SMBCLK Time Low for Reset of 25 ms (min)
Serial Interface
(5)
35 ms (max)
t
SU;DAT
Data In Setup Time to SMBCLK High 250 ns (min)
t
HD;DAT
Data Out Stable after SMBCLK Low 300 ns (min)
1075 ns (max)
t
HD;STA
Start Condition SMBDAT Low to SMBCLK Low 100 ns (min)
(Start condition hold before the first clock falling
edge)
t
SU;STO
Stop Condition SMBCLK High to SMBDAT Low 100 ns (min)
(Stop Condition Setup)
t
SU;STA
SMBus Repeated Start-Condition Setup Time, 0.6 µs (min)
SMBCLK High to SMBDAT Low
(1) Typical figures are at T
A
= 25°C and represent most likely parametric norms at the time of product characterization. The typical
specifications are not ensured.
(2) Limits are specified to Texas Instruments' AOQL (Average Outgoing Quality Level).
(3) The output rise time is measured from (V
IN(0)
max + 0.15V) to (V
IN(1)
min − 0.15V).
(4) The output fall time is measured from (V
IN(1)
min - 0.15V) to (V
IN(1)
min + 0.15V).
(5) Holding the SMBDAT and/or SMBCLK lines Low for a time interval greater than t
TIMEOUT
will reset the LM95241's SMBus state machine,
therefore setting SMBDAT and SMBCLK pins to a high impedance state.
6 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LM95241