Datasheet

LM95241
www.ti.com
SNIS143E AUGUST 2006REVISED MARCH 2013
TEMPERATURE DATA FORMAT
Temperature data can only be read from the Local and Remote Temperature registers .
Remote temperature data with the digital filter off is represented by an 11-bit, two's complement word or
unsigned binary word with an LSb (Least Significant Bit) equal to 0.125°C. The data format is a left justified 16-bit
word available in two 8-bit registers. Unused bits will always report "0".
Table 2. 11-bit, 2's complement (10-bit plus sign)
Temperature Digital Output
Binary Hex
+125°C 0111 1101 0000 0000 7D00h
+25°C 0001 1001 0000 0000 1900h
+1°C 0000 0001 0000 0000 0100h
+0.125°C 0000 0000 0010 0000 0020h
0°C 0000 0000 0000 0000 0000h
0.125°C 1111 1111 1110 0000 FFE0h
1°C 1111 1111 0000 0000 FF00h
25°C 1110 0111 0000 0000 E700h
55°C 1100 1001 0000 0000 C900h
Table 3. 11-bit, unsigned binary
Temperature Digital Output
Binary Hex
+255.875°C 1111 1111 1110 0000 FFE0h
+255°C 1111 1111 0000 0000 FF00h
+201°C 1100 1001 0000 0000 C900h
+125°C 0111 1101 0000 0000 7D00h
+25°C 0001 1001 0000 0000 1900h
+1°C 0000 0001 0000 0000 0100h
+0.125°C 0000 0000 0010 0000 0020h
0°C 0000 0000 0000 0000 0000h
Remote temperature data with the digital filter on is represented by a 13-bit, two's complement word or unsigned
binary word with an LSb (Least Significant Bit) equal to 0.03125°C (1/32°C). The data format is a left justified 16-
bit word available in two 8-bit registers. Unused bits will always report "0".
Table 4. 13-bit, 2's complement
Temperature Digital Output
Binary Hex
+125°C 0111 1101 0000 0000 7D00h
+25°C 0001 1001 0000 0000 1900h
+1°C 0000 0001 0000 0000 0100h
+0.03125°C 0000 0000 0000 1000 0008h
0°C 0000 0000 0000 0000 0000h
0.03125°C 1111 1111 1111 0111 FFF7h
1°C 1111 1111 0000 0000 FF00h
25°C 1110 0111 0000 0000 E700h
55°C 1100 1001 0000 0000 C900h
Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links: LM95241