CONVERSION SEQUENCE
In the power-up default state the LM95235 takes a maximum of 1 second to convert the Local Temperature,
Remote Temperature, and to update all of its registers. Only during the conversion process is the Busy bit (D7) in
Status Register 1 (02h) high. These conversions are addressed in a round-robin sequence. The conversion rate
may be modified by the Conversion Rate bits found in the Conversion Rate Register (R/W: 04h/0Ah). When the
conversion rate is modified a delay is inserted between conversions, the actual maximum conversion time
remains at 72 ms. Different conversion rates will cause the LM95235 to draw different amounts of supply current
as shown in Figure 7.
Figure 7. Conversion Rate Effect on Power Supply Current
POWER-ON-DEFAULT STATES
LM95235 always powers up to these known default states. The LM95235 remains in these states until after the
first conversion.
1. Command Register set to 00h
2. Conversion Rate register defaults to 02h (1 second).
3. Local Temperature set to 0°C until the end of the first conversion
4. Remote Diode Temperature set to 0°C until the end of the first conversion
5. Remote OS limit default is 55h (85°C).
6. Local Shared and TCRIT limit default is 55h (85°C).
7. Remote TCRIT limit default is 6Eh (110°C).
8. Remote Offset High and Low bytes default to 00h.
9. Configuration Register 1 defaults to 00h. This sets the LM95235 as follows:
(a) The STOP/RUN defaults to the active/converting mode.
(b) The Local and Remote TCRIT and OS Masks are reset to 0.
10. Configuration Register 2 defaults to 1Fh. This sets the LM95235 as follows:
(a) Remote Diode digital filter defaults on.
(b) The Remote Diode mode defaults to a typical Intel processor on 65/90 nm process.
(c) Diode Fault Mask bit for TCRIT defaults to 1.
(d) Diode Fault Mask bit for OS defaults to 0.
(e) Pin 6 Function defaults to Address Input function (A0).
SMBus INTERFACE
The LM95235 operates as a slave on the SMBus, so the SMBCLK line is an input and the SMBDAT line is
bidirectional. The LM95235 never drives the SMBCLK line and it does not support clock stretching. According to
SMBus specifications, the LM95235 has a 7-bit slave address. Three SMBus addresses can be selected by
connecting pin 6 (A0) to either Low, Mid-Supply or High voltages. Table 3 shows the possible selections.