Datasheet

LM95234
www.ti.com
SNIS136D AUGUST 2006REVISED MARCH 2013
Bit(s) Bit Name Read/ Description
Write
7–5 - RO Reserved – will report "0" when read.
4 R4T1 RO Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4 Tcrit Limit
register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit register
minus the Common Hysteresis value
3 R3T1 RO Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3 Tcrit Limit
register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit register
minus the Common Hysteresis value
2 R2T1 RO Remote 2 Tcrit-1 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2 Tcrit-1
Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-1 Limit register
minus the Common Hysteresis value
1 R1T1 RO Remote 1 Tcrit-1 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1 Tcrit-1
Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-1 Limit register
minus the Common Hysteresis value
0 LT1 RO Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus the
Common Hysteresis value
Status 3 (TCRIT2)
Status bits for TCRIT2. When one or more of these bits are set and if not masked the TCRIT2 output will
activate. TCRIT2 will deactivate when all these bits are cleared.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Status 3 (TCRIT2) 0x09 RO R4T2 R3T2 R2T2 R1T2 LT2
Bit(s) Bit Name Read/ Description
Write
7–5 - RO Reserved – will report "0" when read.
4 R4T2 RO Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4 Tcrit Limit
register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit register
minus the Common Hysteresis value
3 R3T2 RO Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3 Tcrit Limit
register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit register
minus the Common Hysteresis value
2 R2T2 RO Remote 2 Tcrit-2 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2 Tcrit-2
Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-2 Limit register
minus the Common Hysteresis value
1 R1T2 RO Remote 1 Tcrit-2 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1 Tcrit-2
Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-2 Limit register
minus the Common Hysteresis value
Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 29