Datasheet
LM95233
SNIS145E –AUGUST 2006–REVISED MARCH 2013
www.ti.com
Status 2 (TCRIT1)
Status bits for TCRIT1. When one or more of these bits are set and if not masked the TCRIT1 output will
activate. TCRIT1 will deactivate when all these bits are cleared.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Status 2 (TCRIT1) 0x08 RO – – – – – R2T1 R1T1 LT1 –
Bit(s) Bit Name Read/ Description
Write
7–3 - RO Reserved – will report "0" when read.
2 R2T1 RO Remote 2 Tcrit-1 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2 Tcrit-1
Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-1 Limit register
minus the Common Hysteresis value
1 R1T1 RO Remote 1 Tcrit-1 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1 Tcrit-1
Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-1 Limit register
minus the Common Hysteresis value
0 LT1 RO Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus the
Common Hysteresis value
Status 3 (TCRIT2)
Status bits for TCRIT2. When one or more of these bits are set and if not masked the TCRIT2 output will
activate. TCRIT2 will deactivate when all these bits are cleared.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Status 3 (TCRIT2) 0x09 RO – – – – – R2T2 R1T2 LT2 –
Bit(s) Bit Name Read/ Description
Write
7–3 - RO Reserved – will report "0" when read.
2 R2T2 RO Remote 2 Tcrit-2 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2 Tcrit-2
Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-2 Limit register
minus the Common Hysteresis value
1 R1T2 RO Remote 1 Tcrit-2 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1 Tcrit-2
Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-2 Limit register
minus the Common Hysteresis value
0 LT2 RO Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus the
Common Hysteresis value
28 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LM95233