Datasheet
LM95233
SNIS145E –AUGUST 2006–REVISED MARCH 2013
www.ti.com
Channel Conversion Enable
When a conversion is disabled for a particular channel it is skipped. The continuous conversion rate is effected
all other conversion rates are not effected as extra standby time is inserted in order to compensate. See
Conversion Rate Register description.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Channel Conversion Enable 0x05 R/W – – – – – R2CE R1CE LCE 0x1F
Bit(s) Bit Name Read/ Description
Write
7–3 – RO Reserved – will report "0" when read.
2 R2CE R/W Remote 2 Temperature Conversion Enable
1– Remote 2 temp conversion enabled
0– Remote 2 temp conversion disabled
1 R1CE R/W Remote 1 Temperature Conversion Enable
1– Remote 1 temp conversion enabled
0– Remote 1 temp conversion disabled
0 LCE R/W Local Temperature Conversion Enable
1– Local temp conversion enabled
0– Local temp conversion disabled
Filter Setting
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Filter Setting 0x06 R/W – – – – R2F1 R2F0 R1F1 R1F0 0x0F
Bit(s) Bit Name Read/ Description
Write
7–4 – RO Reserved – will report "0" when read.
3–2 R2F[1:0] R/W Remote Channel 2 Filter Enable Bits
R2F[1:0] Digital Filter State
00 disable all digital filtering
01 enable basic filter
10 reserved (do not use)
11 enable enhanced filter
1–0 R1F[1:0] R/W Remote Channel 1 Filter Enable
R1F[1:0] Filter State
00 disable all digital filtering
01 enable basic filter
10 reserved (do not use)
11 enable enhanced filter
1-Shot
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
1-Shot 0x0F WO – – – – – – – – –
26 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LM95233