Bit(s) Bit Name Read/ Description
Write
5 R3DO RO Remote 3 diode open fault status:
1 – indicates that remote 3 diode has an "open" fault
0 – indicates that remote 3 diode does not have an "open" fault
4 R3DS RO Remote 3 diode short fault status:
1 – indicates that remote 3 diode has a "short" fault
0 – indicates that remote 3 diode does not have a "short" fault
3 R2DO RO Remote 2 diode open fault status:
1 – indicates that remote 2 diode has an "open" fault
0 – indicates that remote 2 diode does not have an "open" fault
2 R2DS RO Remote 2 diode short fault status:
1 – indicates that remote 2 diode has a "short" fault
0 – indicates that remote 2 diode does not have a "short" fault
1 R1DO RO Remote 1 diode open fault status:
1 – indicates that remote 1 diode has an "open" fault
0 – indicates that remote 1 diode does not have an "open" fault
0 R1DS RO Remote 1 diode short fault status:
1 – indicates that remote 1 diode has a "short" fault
0 – indicates that remote 1 diode does not have a "short" fault
Status 2 (TCRIT1)
Status bits for TCRIT1. When one or more of these bits are set and if not masked the TCRIT1 output will
activate. TCRIT1 will deactivate when all these bits are cleared.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Status 2 (TCRIT1) 0x08 RO R4T1 R3T1 R2T1 R1T1 LT1
Bit(s) Bit Name Read/ Description
Write
7–5 - RO Reserved – will report "0" when read.
4 R4T1 RO Remote 4 Tcrit Status:
1 – indicates that remote 4 reading is greater than or equal to the value set in Remote 4 Tcrit Limit
register
0 – indicates that that remote 4 reading is less than the value set in Remote 4 Tcrit Limit register
minus the Common Hysteresis value
3 R3T1 RO Remote 3 Tcrit Status:
1 – indicates that remote 3 reading is greater than or equal to the value set in Remote 3 Tcrit Limit
register
0 – indicates that that remote 3 reading is less than the value set in Remote 3 Tcrit Limit register
minus the Common Hysteresis value
2 R2T1 RO Remote 2 Tcrit-1 Status:
1 – indicates that remote 2 reading is greater than or equal to the value set in Remote 2 Tcrit-1
Limit register
0 – indicates that that remote 2 reading is less than the value set in Remote 2 Tcrit-1 Limit register
minus the Common Hysteresis value
1 R1T1 RO Remote 1 Tcrit-1 Status:
1 – indicates that remote 1 reading is greater than or equal to the value set in Remote 1 Tcrit-1
Limit register
0 – indicates that that remote 1 reading is less than the value set in Remote 1 Tcrit-1 Limit register
minus the Common Hysteresis value
0 LT1 RO Local Tcrit Status:
1 – indicates that local reading is greater than or equal to the value set in Local Tcrit Limit register
0 – indicates that local reading is less than the value set in Local Tcrit Limit register minus the
Common Hysteresis value