SNIS146A MARCH 2007REVISED MARCH 2013
www.ti.com
1-Shot
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
1-Shot 0x0F WO
Bit(s) Bit Name Read/ Description
Write
7–0 - WO Writing to this register activates one conversion for all the enabled channels if
the chip is in standby mode (i.e. standby bit = 1). The actual data written does
not matter and is not stored.
STATUS REGISTERS
Common Status Register
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Common Status Register 0x02 RO BUSY NR SR4F SR3F SR2F SR1F 0x00
Bit(s) Bit Name Read/ Description
Write
7 BUSY RO Busy bit (device converting)
6 NR RO Not Ready bit (30 ms), indicates power up initialization sequence is in progress
5–4 RO Reserved – will report "0" when read.
3 SR4F RO Status Register 4 Flag:
1 – indicates that Status Register 4 has at least one bit set
0 – indicates that all of Status Register 4 bits are cleared
2 SR3F RO Status Register 3 Flag:
1 – indicates that Status Register 3 has at least one bit set
0 – indicates that all of Status Register 3 bits are cleared
1 SR2F RO Status Register 2 Flag:
1 – indicates that Status Register 2 has at least one bit set
0 – indicates that all of Status Register 2 bits are cleared
0 SR1F RO Status Register 1 Flag:
1 – indicates that Status Register 1 has at least one bit set
0 – indicates that all of Status Register 1 bits are cleared
Status 1 Register (Diode Fault)
Status fault bits for open or shorted diode (i.e. Short Fault: D+ shorted to Ground or D-; Open Fault: D+ shorted
to V
DD
, or floating). During fault conditions the temperature reading is 0 °C if unsigned value registers are read or
–128.000 °C if signed value registers are read.
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Status 1 (Diode Fault) 0x07 RO R4DO R4DS R3DO R3DS R2DO R2DS R1DO R1DS
Bit(s) Bit Name Read/ Description
Write
7 R4DO RO Remote 4 diode open fault status:
1 – indicates that remote 4 diode has an "open" fault
0 – indicates that remote 4 diode does not have an "open" fault
6 R4DS RO Remote 4 diode short fault status:
1 – indicates that remote 4 diode has a "short" fault
0 – indicates that remote 4 diode does not have a "short" fault
28 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: LM95214