Bit(s) Bit Name Read/ Description
Write
7 SIGN R/W Sign bit All registers have 2’s complement format.
The offset range for each remote is
6 32 R/W bit weight 32°C
+63.5°C/64°C. The value programmed in
5 16 R/W bit weight 16°C
this register is directly added to the actual
reading of the ADC and the modified number
4 8 R/W bit weight 8°C
is reported in the remote value registers.
3 4 R/W bit weight 4°C
2 2 R/W bit weight 2°C
1 1 R/W bit weight 1°C
0 1/2 R/W bit weight 1/2°C (0.5°C)
CONFIGURATION REGISTERS
Main Configuration Register
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Configuration 0x03 R/W STBY R4QE R3QE 0x03
Bit(s) Bit Name Read/ Description
Write
7 RO Reserved will report "0" when read.
6 STBY R/W Software Standby
1 – standby (when in this mode one conversion sequence can be initiated by writing to the
one-shot register)
0 – active/converting
5–2 RO Reserved – will report "0" when read.
1 R4QE R/W Fault queue enable for Remote 4
1– Fault queue enabled
0– Fault queue disabled
0 R3QE R/W Fault queue enable for Remote 3
1– Fault queue enabled
0– Fault queue disabled
Conversion Rate Register
Register Name Command Read/ D7 D6 D5 D4 D3 D2 D1 D0 POR
Byte Write Default
(Hex) (Hex)
Conversion Rate 0x04 R/W CR1 CR0 0x02
Bit(s) Bit Name Read/ Description
Write
7-2 RO Reserved – will report "0" when read.
1-0 CR[1:0] R/W Conversion rate control bits modify the time interval for conversion of the channels enabled.
The channels enabled are converted sequentially then standby mode enabled for the
remainder of the time interval.
CR[1:0] Conversion Rate
00 continuous (30 ms to 143 ms)
01 0.364 s
10 1s
11 2.5 s