D4: T_CRIT mask for Remote temperature, when set to 1 a remote temperature reading that exceeds T_CRIT
setpoint will not activate the T_CRIT_A pin.
D3: T_CRIT mask, this bit must be set to a 1 before the T_CRIT setpoint is lowered below 127 in order for
T_CRIT_A pin to function properly.
D2: T_CRIT mask for Local reading, when set to 1 a Local temperature reading that exceeds T_CRIT setpoint
will not activate the T_CRIT_A pin.
D1: INT active state inversion. When INT Inversion is set to a 1 the active state of the INT output will be a logical
high. A low would then select an active state of a logical low.
D6 and D0: These bits are always set to 0 and reserved for future use. A write of 1 will return a 0 when read.
LOCAL AND REMOTE HIGH SETPOINT REGISTERS (LHS, RHS)
Table 4. LOCAL AND REMOTE HIGH SETPOINT REGISTERS (LHS, RHS) (Read Address 05h, 07h/Write
Address 0Bh, 0Dh):
D7 D6 D5 D4 D3 D2 D1 D0
MSB Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 LSB
D7–D0: HIGH setpoint temperature data. Power up default is LHIGH = RHIGH=127°C.
T_CRIT REGISTER (TCS)
Table 5. T_CRIT REGISTER (TCS) (Read Address 42h/Write Address 5Ah):
D7 D6 D5 D4 D3 D2 D1 D0
MSB Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 LSB
D7–D0: T_CRIT setpoint temperature data. Power up default is T_CRIT = 127°C.
16 Submit Documentation Feedback Copyright © 2000–2013, Texas Instruments Incorporated
Product Folder Links: LM82