Typical Applications (Continued)
Characteristic Condition Typical
Value
Output Voltage I
O
=
50 mA 25V
Line Regulation 5.0V ≤ V
I
≤ 15V 4.0 mV
Load Regulation 5.0 mA ≤ I
O
2.0 mV
I
O
≤ 100 mA
Max Output Current V
O
=
23.75V 160 mA
Output Ripple I
O
=
50 mA 30 mV
Efficiency I
O
=
50 mA 79
%
Standby Current I
O
=
50 mA 2.6 mA
Characteristic Condition Typical
Value
Output Voltage I
O
=
100 mA −15V
Line Regulation 8.0V ≤ V
I
≤ 18V 5.0 mV
Load Regulation 5.0 mA ≤ I
O
3.0 mV
I
O
≤ 150 mA
Max Output Current V
O
=
14.25V 160 mA
Output Ripple I
O
=
100 mA 20 mV
Efficiency I
O
=
100 mA 70
%
Standby Current I
O
=
100 mA 2.3 mA
DS010057-4
FIGURE 2. Typical Step-Up Regulator and
Operational Performance (T
A
=
25˚C)
DS010057-5
FIGURE 3. Typical Inverting Regulator and
Operational Performance (T
A
=
25˚C)
7 www.national.com