Datasheet
LM6172
SNOS792D –MAY 1999–REVISED MARCH 2013
www.ti.com
Figure 48. Properly Terminated Signal
Figure 49. Improperly Terminated Signal
To minimize reflection, coaxial cable with matching characteristic impedance to the signal source should be
used. The other end of the cable should be terminated with the same value terminator or resistor. For the
commonly used cables, RG59 has 75Ω characteristic impedance, and RG58 has 50Ω characteristic impedance.
POWER DISSIPATION
The maximum power allowed to dissipate in a device is defined as:
P
D
= (T
J(max)
− T
A
)/θ
JA
18 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated
Product Folder Links: LM6172