Datasheet
LM5118, LM5118-Q1
SNVS566H –APRIL 2008–REVISED JANUARY 2014
www.ti.com
Absolute Maximum Ratings
(1)
VIN, EN, VOUT to GND –0.3 V to 76 V
VCC, LO, VCCX, UVLO to GND
(2)
–0.3 to 15 V
HB to HS –0.3 to 15 V
HO to HS –0.3 to HB +0.3 V
HS to GND –4 V to 76 V
CSG, CS to GND –0.3V to +0.3 V
RAMP, SS, COMP, FB, SYNC, RT to GND –0.3 to 7 V
ESD Rating
HBM
(3)
2 kV
Storage Temperature Range –55°C to +150°C
Junction Temperature +150°C
(1) Absolute Maximum Ratings are limits beyond which damage to the device may occur.
(2) These pins must not be raised above VIN.
(3) The human body model is a 100 pF capacitor discharged through a 1.5 kΩ resistor into each pin.
Recommended Operating Conditions
(1)
VIN
(2)
3 V to 75 V
VCC, VCCX 4.75 V to 14 V
Junction Temperature –40°C to +125°C
(1) Operating Ratings indicate conditions for which the device is intended to be functional, but does not ensure specific performance limits.
For specifications and test conditions see Electrical Characteristics.
(2) 5V VIN is required to initially start the controller.
4 Submit Documentation Feedback Copyright © 2008–2014, Texas Instruments Incorporated
Product Folder Links: LM5118 LM5118-Q1