Datasheet

LM5066
SNVS655G JUNE 2011REVISED FEBRUARY 2013
www.ti.com
MFR_SPECIFIC_18: AVG_BLOCK_READ (E2h)
The AVG_BLOCK_READ command concatenates the DIAGNOSTIC_WORD with input and output average
telemetry information (IIN, VOUT, VIN, PIN) as well as temperature to capture all of the operating information of
the part in a single PMBus transaction. The block is 12 bytes long with telemetry information being sent out in the
same manner as if an individual READ_AVG_XXX command had been issued (shown below).
AVG_BLOCK_READ also specifies that the VIN, VOUT, and IIN measurements are all time-aligned whereas
there is a chance they may not be if read with individual PMBus commands. To read data from the
AVG_BLOCK_READ command, use the SMBus Block Read protocol.
Table 39. AVG_BLOCK_READ Register Format
Byte Count (always 12) (1 byte)
DIAGNOSTIC_WORD (1 word)
AVG_IIN (1 word)
AVG_VOUT (1 word)
AVG_VIN (1 word)
AVG_PIN (1 word)
TEMPERATURE (1 word)
46 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LM5066