Datasheet

LM5066
SNVS655G JUNE 2011REVISED FEBRUARY 2013
www.ti.com
Table 32. SAMPLES_FOR_AVG Register (continued)
AVGN N = 2
AVGN
Averaging/Register Update Period (ms)
0011 8 8
0100 16 16
0101 32 32
0110 64 64
0111 128 128
1000 256 256
1001 512 512
1010 1024 1024
1011 2048 2048
1100 4096 4096
Note that a change in the SAMPLES_FOR_AVG register will not be reflected in the average telemetry
measurements until the present averaging interval has completed. The default setting for AVGN is 0000,
therefore, the average telemetry will mirror the instantaneous telemetry until a value higher than zero is
programmed.
The SAMPLES_FOR_AVG register is accessed via the PMBus read / write byte protocol.
Table 33. SAMPLES_FOR_AVG Register
Value Meaning Default
0h – 0Ch Exponent (AVGN) for number of samples to 00h
average over
MFR_SPECIFIC_12: READ_AVG_VIN (DCh)
The READ_AVG_VIN command will report the 12-bit ADC measured input average voltage. If the data is not
ready, the returned value will be the previous averaged data. However, if there is no previously averaged data,
the default value (0000h) will be returned. This data is read with the PMBus Read Word protocol. This register
should use the coefficients shown in Table 41.
Table 34. READ_AVG_VIN Register
Value Meaning Default
0h – 0FFFh Average of measured values for input 0000h
voltage
MFR_SPECIFIC_13: READ_AVG_VOUT (DDh)
The READ_AVG_VOUT command will report the 12-bit ADC measured current sense average voltage. The
returned value will be the default value (0000h) or previous data when the average data is not ready. This data is
read with the PMBus Read Word protocol. This register should use the coefficients shown in Table 41.
Table 35. READ_AVG_VOUT Register
Value Meaning Default
0h – 0FFFh Average of measured values for output 0000h
voltage
MFR_SPECIFIC_14: READ_AVG_IIN (DEh)
The READ_AVG_IIN command will report the 12-bit ADC measured current sense average voltage. The returned
value will be the default value (0000h) or previous data when the average data is not ready. This data is read
with the PMBus Read Word protocol. This register should use the coefficients shown in Table 41.
44 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LM5066