MANUFACTURER SPECIFIC PMBUS™ COMMANDS
MFR_SPECIFIC_00: READ_VAUX (D0h)
The READ_VAUX command will report the 12-bit ADC measured auxiliary voltage. Voltages greater than or
equal to 2.97V to ground will be reported at plus full scale (0FFFh). Voltages less than or equal to 0V referenced
to ground will be reported as 0 (0000h). To read data from the READ_VAUX command, use the PMBus Read
Word protocol.
Table 22. READ_VAUX Register
Value Meaning Default
0h – 0FFFh Measured value for VAUX input 0000h
MFR_SPECIFIC_01: MFR_READ_IIN (D1h)
The MFR_READ_IIN command will report the 12-bit ADC measured current sense voltage. To read data from
the MFR_READ_IIN command, use the PMBus Read Word protocol. Reading this register should use the
coefficients shown in Table 41. Please see the section on coefficient calculations to calculate the values to use.
Table 23. MFR_READ_IIN Register
Value Meaning Default
0h – 0FFFh Measured value for input current sense 0000h
voltage
MFR_SPECIFIC_02: MFR_READ_PIN (D2h)
The MFR_READ_PIN command will report the upper 12 bits of the VIN x IIN product as measured by the 12-bit
ADC. To read data from the MFR_READ_PIN command, use the PMBus Read Word protocol. Reading this
register should use the coefficients shown in Table 41. Please see the section on coefficient calculations to
calculate the values to use.
Table 24. MFR_READ_PIN Register
Value Meaning Default
0h – 0FFFh Value for input current x input voltage 0000h
MFR_SPECIFIC_03: MFR_IN_OC_WARN_LIMIT (D3h)
The MFR_IIN_OC_WARN_LIMIT PMBus command sets the input over-current warning threshold. In the event
that the input current rises above the value set in this register, the IIN Over-current flags are set in the respective
registers and the SMBA is asserted. To access the MFR_IIN_OC_WARN_LIMIT register, use the PMBus
Read/Write Word protocol. Reading/writing to this register should use the coefficients shown in Table 41.
Table 25. MFR_IIN_OC_WARN_LIMIT Register
Value Meaning Default
0h – 0FFEh Value for input over-current warn limit 0FFFh
0FFFh Input over-current warning disabled n/a
40 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated