Datasheet
LM5066
SNVS655G –JUNE 2011–REVISED FEBRUARY 2013
www.ti.com
READ_VOUT (8Bh)
The READ_VOUT command is a standard PMBus command that returns the 12-bit measured value of the output
voltage. Reading this register should use the coefficients shown in Table 41. Accesses to this command should
use the PMBus read word protocol. This value is also used internally for the VOUT Under Voltage Warning
detection.
Table 17. READ_VOUT Register
Value Meaning Default
0h – 0FFFh Measured value for VOUT 0000h
READ_TEMPERATURE_1 (8Dh)
The READ_TEMPERATURE_1 command is a standard PMBus command that returns the signed value of the
temperature measured by the external temperature sense diode. Reading this register should use the coefficients
shown in Table 41. Accesses to this command should use the PMBus read word protocol. This value is also
used internally for the Over Temperature Fault and Warning detection. This data has a range of -256°C to +
255°C after the coefficients are applied.
Table 18. READ_TEMPERATURE_1 Register
Value Meaning Default
0h – 0FFFh Measured value for TEMPERATURE 0000h
MFR_ID (99h)
The MFR_ID command is a standard PMBus command that returns the identification of the manufacturer. To
read the MFR_ID, use the PMBus block read protocol.
Table 19. MFR_ID Register
Byte Name Value
0 Number of bytes 03h
1 MFR ID-1 4Eh ‘N’
2 MFR ID-2 53h ‘S’
3 MFR ID-3 43h ‘C’
MFR_MODEL (9Ah)
The MFR_MODEL command is a standard PMBus command that returns the part number of the chip. To read
the MFR_MODEL, use the PMBus block read protocol.
Table 20. MFR_MODEL Register
Byte Name Value
0 Number of bytes 08h
1 MFR ID-1 4Ch ‘L’
2 MFR ID-2 4Dh ‘M’
3 MFR ID-3 35h ‘5’
4 MFR ID-4 30h ‘0’
5 MFR ID-5 36h ‘6’
6 MFR ID-6 36h ‘6’
7 MFR ID-7 00h
8 MFR ID-8 00h
38 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LM5066