Table 1. Supported PMBus Commands (continued)
Number
Default
Code Name Function R/W Of Data
Value
Bytes
D6h MFR_SPECIFIC_06 Resets the contents of the peak input power register to zero. Send 0
CLEAR_PIN_PEAK Byte
D7h MFR_SPECIFIC_07 Allows the user to disable MOSFET gate shutdown for R/W 1 0000h
GATE_MASK various fault conditions.
D8h MFR_SPECIFIC_08 Retrieves or stores user SMBA fault mask. R/W 2 0820h
ALERT_MASK
D9h MFR_SPECIFIC_09 Retrieves or stores information about number of retry R/W 1 0000h
DEVICE_SETUP attempts.
DAh MFR_SPECIFIC_10 Retrieves most recent diagnostic and telemetry information in R 12 0190h
BLOCK_READ a single transaction. 0000h
0000h
0000h
0000h
0000h
DBh MFR_SPECIFIC_11 Exponent value AVGN for number of samples to be averaged R/W 1 00h
SAMPLES_FOR_AVG (N = 2
AVGN
), range = 00h to 0Ch .
DCh MFR_SPECIFIC_12 Retrieves averaged input voltage measurement. R 2 0000h
READ_AVG_VIN
DDh MFR_SPECIFIC_13 Retrieves averaged output voltage measurement. R 2 0000h
READ_AVG_VOUT
DEh MFR_SPECIFIC_14 Retrieves averaged input current measurement. R 2 0000h
READ_AVG_IIN
DFh MFR_SPECIFIC_15 Retrieves averaged input power measurement. R 2 0000h
READ_AVG_PIN
E0h MFR_SPECIFIC_16 Captures diagnostic and telemetry information which are R 12 0000h
BLACK_BOX_READ latched when the first SMBA event after faults are cleared. 0000h
0000h
0000h
0000h
0000h
E1h MFR_SPECIFIC_17 Manufacturer-specific parallel of the STATUS_WORD to R 2 08E0h
DIAGNOSTIC_WORD_READ convey all FAULT/WARN data in a single transaction.
E2h MFR_SPECIFIC_18 Retrieves most recent average telemetry and diagnostic R 12 0000h
AVG_BLOCK_READ information in a single transaction. 0000h
0000h
0000h
0000h
0000h
32 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LM5066