Datasheet

LM5066
www.ti.com
SNVS655G JUNE 2011REVISED FEBRUARY 2013
PMBUS
COMMAND SUPPORT
The device features an SMBus interface that allows the use of PMBus commands to set warn levels, error
masks, and get telemetry on V
IN
, V
OUT
, I
IN
, V
AUX
, and P
IN
. The supported PMBus commands are shown in
Table 1.
Table 1. Supported PMBus Commands
Number
Default
Code Name Function R/W Of Data
Value
Bytes
01h OPERATION Retrieves or stores the operation status. R/W 1 80h
03h CLEAR_FAULTS Clears the status registers and re-arms the Black Box Send 0
registers for updating. Byte
19h CAPABILITY Retrieves the device capability. R 1 B0h
43h VOUT_UV_WARN_LIMIT Retrieves or stores output under-voltage warn limit threshold. R/W 2 0000h
4Fh OT_FAULT_LIMIT Retrieves or stores over temperature fault limit threshold. R/W 2 0960h
(150°C)
51h OT_WARN_LIMIT Retrieves or stores over temperature warn limit threshold. R/W 2 07D0h
(125°C)
57h VIN_OV_WARN_LIMIT Retrieves or stores input over-voltage warn limit threshold. R/W 2 0FFFh
58h VIN_UV_WARN_LIMIT Retrieves or stores input under-voltage warn limit threshold. R/W 2 0000h
78h STATUS_BYTE Retrieves information about the parts operating status. R 1 49h
79h STATUS_WORD Retrieves information about the parts operating status. R 2 3849h
7Ah STATUS_VOUT Retrieves information about output voltage status. R 1 00h
7Ch STATUS_INPUT Retrieves information about input status. R 1 10h
7Dh STATUS_TEMPERATURE Retrieves information about temperature status. R 1 00h
7Eh STATUS_CML Retrieves information about communications status. R 1 00h
80h STATUS_MFR_SPECIFIC Retrieves information about circuit breaker and MOSFET R 1 10h
shorted status.
88h READ_VIN Retrieves input voltage measurement. R 2 0000h
8Bh READ_VOUT Retrieves output voltage measurement. R 2 0000h
8Dh READ_TEMPERATURE_1 Retrieves temperature measurement. R 2 0190h
99h MFR_ID Retrieves manufacturer ID in ASCII characters (NSC). R 3 4Eh
53h
43h
9Ah MFR_MODEL Retrieves Part number in ASCII characters. (LM5066\0\0). R 8 4Ch
4Dh
35h
30h
36h
36h
0h
0h
9Bh MFR_REVISION Retrieves part revision letter/number in ASCII (for example, R 2 41h
AA). 41h
D0h MFR_SPECIFIC_00 Retrieves auxiliary voltage measurement. R 2 0000h
READ_VAUX
D1h MFR_SPECIFIC_01 Retrieves input current measurement. R 2 0000h
MFR_READ_IIN
D2h MFR_SPECIFIC_02 Retrieves input power measurement. R 2 0000h
MFR_READ_PIN
D3h MFR_SPECIFIC_03 Retrieves or stores input current limit warn threshold. R/W 2 0FFFh
MFR_IIN_OC_WARN_LIMIT
D4h MFR_SPECIFIC_04 Retrieves or stores input power limit warn threshold. R/W 2 0FFFh
MFR_PIN_OP_WARN_LIMIT
D5h MFR_SPECIFIC_05 Retrieves measured peak input power measurement. R 2 0000h
READ_PIN_PEAK
Copyright © 2011–2013, Texas Instruments Incorporated Submit Documentation Feedback 31
Product Folder Links: LM5066