Datasheet
Performance Characteristics
www.ti.com
9 Performance Characteristics
9.1 Turn-on Waveforms
When applying power to the LM5041 evaluation board a certain sequence of events must occur. Soft-start
capacitor values and other components allow for a minimal output voltage for a short time until the
feedback loop can stabilize without overshoot. Figure 3 and Figure 4 show typical turn-on waveforms at no
load and at a load of 50A. Input voltage, output voltage and output current are shown.
9.2 Output Ripple Waveforms
Figure 5 shows output ripple for a load of 40A. The waveforms should be measured directly across the
output capacitors using a short tip-type ground lead on the scope probe. Bandwidth limiting may also
prove useful.
Trace 1: Input Voltage, no load Volts/div = 10.0V
Trace 2: Output Voltage, no load Volts/div = 1.0V
Trace 3: Output Current, no load Amps/div = 20.0A
Horizontal Resolution = 1µs/div
Figure 3. Typical Turn-on Waveform at No Load
Trace 1: Input Voltage, no loadVolts/div = 10.0V
Trace 2: Output Voltage, no load Volts/div = 1.0V
Trace 3: Output Current, no load Amps/div = 20.0A
Horizontal Resolution = 1µs/div
Figure 4. Typical Turn-on Waveform at a Load of 50A
4
AN-1299 LM5041 Evaluation Board SNVA074A–May 2004–Revised May 2013
Submit Documentation Feedback
Copyright © 2004–2013, Texas Instruments Incorporated