Datasheet

LM5035
SNVS428G JANUARY 2006REVISED MARCH 2013
www.ti.com
PIN DESCRIPTIONS (continued)
HTSSOP WQFN
Name Description Application Information
PIN PIN
Input to the Start-up Regulator. Operating input range is 13V to
100V with transient capability to 105V. For power sources outside of
20 21 VIN Input voltage source
this range, the LM5035 can be biased directly at VCC by an
external regulator.
Exposed Pad, underside of No electrical contact. Connect to system ground plane for reduced
EP EP EP
package thermal resistance.
1 NC No connection No electrical contact.
10 NC No connection No electrical contact.
20 NC No connection No electrical contact.
22 NC No connection No electrical contact.
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)(2)
VIN to GND -0.3V to 105V
HS to GND -1V to 105V
HB to GND -0.3V to 118V
HB to HS -0.3V to 18V
VCC to GND -0.3V to 16V
CS, RT, DLY to GND -0.3V to 5.5V
COMP Input Current 10mA
All other inputs to GND -0.3V to 7V
ESD Rating
(3)
Human Body Model 2kV
Storage Temperature Range -65°C to 150°C
Junction Temperature 150°C
(1) Absolute Maximum Ratings are limits beyond which damage to the device may occur. Operating Ratings are conditions under which
operation of the device is intended to be functional. For ensured specifications and test conditions, see the Electrical Characteristics.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3) The human body model is a 100 pF capacitor discharged through a 1.5 k resistor into each pin. 2kV for all pins except HB, HO and HS
which are rated at 1.5kV.
Operating Ratings
(1)
VIN Voltage 13V to 105V
External Voltage Applied to VCC 8V to 15V
Operating Junction Temperature -40°C to +125°C
(1) Absolute Maximum Ratings are limits beyond which damage to the device may occur. Operating Ratings are conditions under which
operation of the device is intended to be functional. For ensured specifications and test conditions, see the Electrical Characteristics.
4 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LM5035