Datasheet

LM5030
SNVS215C APRIL 2003REVISED MARCH 2013
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1)(2)
V
IN
to GND (Survival) -0.3V to 100V
V
CC
to GND (Survival) -0.3V to 16V
RT to GND (Survival) -0.3V to 5.5V
All other pins to GND (Survival) -0.3V to 7V
Power Dissipation Internally Limited
ESD Rating
(3)
Human Body Model 2kV
Machine Model 200V
Lead Temperature
(Soldering 4 seconds) 260°C
Storage Temperature Range -55°C to +150°C
Junction Temperature 150°C
(1) Absolute Maximum Ratings are limits beyond which damage to the device may occur. Operating Ratings are conditions under which
operation of the device is intended to be functional. For specifications and test conditions, see the Electrical Characteristics.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
(3) The human body model is a 100pF capacitor discharged through a 1.5k resistor into each pin. The machine model is a 200pF
capacitor discharged directly into each pin. The machine model ESD rating for pin 5 and pin 6 is 150V.
Operating Ratings
Junction Temperature -40°C to +105°C
V
IN
14V to 90V
Electrical Characteristics
Specifications in standard type face are for T
J
= +25°C and those in boldface type apply over the full operating junction
temperature range. Unless otherwise specified: V
IN
= 48V, V
CC
= 10V, and RT = 26.7K
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
Startup Regulator
V
CC
Reg V
CC
Regulation open ckt 7.4 7.7 8.0 V
V
CC
Current Limit See 10 17 mA
I-V
IN
Startup Regulator Leakage V
IN
= 90V 150 500 µA
(external Vcc Supply)
I
IN
Shutdown Current SS = 0V, V
CC
= open 250 350 µA
V
CC
Supply
V
CC
undervoltage Lockout Voltage VccReg VccReg - V
- 300mV 100mV
Undervoltage Hysteresis 1.2 1.6 2.1 V
I
CC
Supply Current Cload = 0 2 3 mA
(1) Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlation using
Statistical Quality Control (SQC) methods. The limits are used to calculate TI's Average Outgoing Quality Level (AOQL).
(2) Typical numbers represent the most likely parametric norm for 25°C operation.
4 Submit Documentation Feedback Copyright © 2003–2013, Texas Instruments Incorporated
Product Folder Links: LM5030