Datasheet
LM5015
SNVS538C –NOVEMBER 2007–REVISED APRIL 2013
www.ti.com
Figure 26. Isolated Two-Switch Flyback
DC-DC TRANSFORMER
The DC-DC transformer shown in Figure 27 provides a 1:1 input voltage to output voltage conversion with
ground isolation. The circuit operates in open loop manner operating at the maximum duty cycle limit of the
LM5015. The power transformer primary-secondary turns ratio is 1:2 (primary to secondary). Therefore, at the
maximum duty cycle of 0.5, the output voltage will be approximately equal to the input voltage. A Zener diode Z1
is used at the output rail as a simple means to protect the output against over-voltage under light and no load
conditions. The maximum load of this example circuit is 0.3A, and the operating voltage range is from 5V to 15V.
Figure 27. DC-DC Transformer
22 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: LM5015