Datasheet
LM4936
www.ti.com
SNAS269A –APRIL 2005–REVISED APRIL 2013
Electrical Characteristics for Control Interface
(1) (2)
The following specifications apply for V
DD
= 5V, V
DD
= 3V and 2.4V ≤ I
2
C/SPI V
DD
≤ 5.5V. Limits apply for T
A
= 25°C.
LM4936
Units
Symbol Parameter Conditions
(Limits)
Typical
(3)
Limit
(4)
t
1
SCL period 2.5 μs (min)
t
2
SDA Set-up Time 100 ns (min)
t
3
SDA Stable Time 0 ns (min)
t
4
Start Condition Time 100 ns (min)
t
5
Stop Condition Time 100 ns (min)
V
IH
Digital Input High Voltage 0.7 X V (min)
I
2
C/SPIV
DD
V
IL
Digital Input Low Voltage 0.3 X V (max)
I
2
C/SPIV
DD
t
ES
SPI ENABLE Setup Time 50 ns (min)
t
EH
SPI ENABLE Hold Time 50 ns (min)
t
EL
SPI ENABLE High Time 50 ns (min)
t
DS
SPI DATA Setup Time 50 ns (min)
t
DH
SPI DATA HOLD Time 50 ns (min)
t
CS
SPI CLOCK Setup Time 50 ns (min)
t
CH
SPI CLOCK High Pulse Width 100 ns (min)
t
CL
SPI CLOCK Low Pulse Width 100 ns (min)
f
CLK
SPI CLOCK Frequency 5 MHz (max)
(1) All voltages are measured with respect to the ground pins, unless otherwise specified. All specifications are tested using the typical
application as shown in Figure 2.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which ensure specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not specified for parameters where no limit is given, however, the typical value is a good indication
of device performance.
(3) Typicals are measured at 25°C and represent the parametric norm.
(4) Limits are specified to Texas Instruments' AOQL ( Average Outgoing Quality Level). Datasheet min/max specification limits are specified
by design, test, or statistical analysis.
Electrical Characteristics for Single-Ended Mode Operation
(1)(2)
The following specifications apply for V
DD
= 5V. Limits apply for T
A
= 25°C.
LM4936
Units
Symbol Parameter Conditions
(Limits)
Typical
(3)
Limit
(4)
P
O
Output Power THD = 1%; f = 1kHz; R
L
= 32Ω 90 mW
THD = 10%; f = 1 kHz; R
L
= 32Ω 110 mW
THD+N Total Harmonic Distortion+Noise P
OUT
= 20mW, f = 1kHz, R
L
= 32Ω, 0.02 %
A
VD
= 1, 80kHz BW
PSRR Power Supply Rejection Ratio C
B
= 1μF, f = 120Hz, 57 dB
Input Terminated
V
RIPPLE
= 200mVp-p
N
OUT
Output Noise A-Wtd Filter 18 µV
X
talk
Channel Separation
(5)
f = 1kHz, C
B
= 1μF 63 dB
(1) All voltages are measured with respect to the ground pins, unless otherwise specified. All specifications are tested using the typical
application as shown in Figure 2.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which ensure specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not specified for parameters where no limit is given, however, the typical value is a good indication
of device performance.
(3) Typicals are measured at 25°C and represent the parametric norm.
(4) Limits are specified to Texas Instruments' AOQL ( Average Outgoing Quality Level). Datasheet min/max specification limits are specified
by design, test, or statistical analysis.
(5) PCB design will affect Crosstalk performance.
Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: LM4936