Datasheet

LM49350, LM49350RLEVAL
www.ti.com
SNAS359D SEPTEMBER 2008REVISED JUNE 2012
TIMING CHARACTERISTICS: DV
DD
= I/OV
DD
= 1.8V
(1)(2)
The following specifications apply for R
L(SP)
= 8, R
L(HP)
= 32, f = 1kHz, unless otherwise specified. Limits apply for T
A
=
25°C.
LM49350
Units
Symbol Parameter Conditions
Typical
(
(Limit)
Limit
(4)
3)
PLL
Minimum MCLK Frequency 0.5 MHz (min)
f
IN
PLL Input Frequency Range
Maximum MCLK Frequency 50 MHz (max)
I
2
S MASTER TIMING
I2S_CLK
PER
I2S_CLK Period I
2
S Master 81.38 ns
tCLK_L I2S_CLK Low Time I
2
S Master 37 ns
tCLK_H I2S_CLK High Time I
2
S Master 37 ns
WS Propagation Delay from I2S_CLK
t
WS_DLY
I
2
S Master 21 ns
falling edge
SDO Propagation Delay from I2S_CLK
t
SDO_DLY
I
2
S Master 21 ns
falling edge
SDI Setup Time to I2S_CLK Rising
t
DST
I
2
S Master 20 ns
Edge
t
DHT
SDI Hold Time to I2S_CLK Rising Edge I
2
S Master 20 ns
I
2
S SLAVE TIMING
I2S_CLK
PER
I2S_CLK Period I
2
S Slave 81.38 ns (min)
tCLK_L I2S_CLK Low Time I
2
S Slave 37 ns (min)
tCLK_H I2S_CLK High Time I
2
S Slave 37 ns (min)
SDO Propagation Delay from I2S_CLK
t
SDO_DLY
I
2
S Slave 21 ns
falling edge
SDI Setup Time to I2S_CLK Rising
t
DST
I
2
S Slave 20 ns (min)
Edge
t
DHT
SDI Hold Time to I2S_CLK Rising Edge I
2
S Slave 20 ns (min)
WS Setup Time to I2S_CLK Rising
t
WS_ST
I
2
S Slave 20 ns (min)
Edge
t
WS_HT
WS Hold Time to I2S_CLK Rising Edge I
2
S Slave 20 ns (min)
(1) “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied. The Recommended Operating
Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions. All
voltages are measured with respect to the ground pin, unless otherwise specified.
(2) The Electrical Characteristics tables list ensured specifications under the listed Recommended Operating Conditions except as
otherwise modified or specified by the Electrical Characteristics Conditions and/or Notes. Typical specifications are estimations only and
are not ensured.
(3) Typical values represent most likely parametric norms at T
A
= +25ºC, and at the Recommended Operation Conditions at the time of
product characterization and are not ensured.
(4) Datasheet min/max specification limits are specified by test or statistical analysis.
Copyright © 2008–2012, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: LM49350 LM49350RLEVAL