SNAS152M MAY 2004REVISED JUNE 2011
Electrical Characteristics V
DD
= 3.3V
(1)(2)(3)
The following specifications apply for V
DD
= 3.3V, R
L
= 16, and C
B
= 4.7µF unless otherwise specified.
Limits apply to T
A
= 25°C.
LM4911 LM4911Q
Units
Symbol Parameter Conditions
(Limits)
Typ
(4)
Limit
(5)
Typ
(4)
Limit
(5)
V
IN
= 0V, I
O
= 0A
I
DD
Quiescent Current T
A
= +25°C 1.5 3 1.5 3 mA (max)
T
A
= –40°C to +105°C 4 mA (max)
V
SHUTDOWN
= GND
I
SD
Shutdown Current T
A
= +25°C 0.1 2 0.1 2 µA (max)
T
A
= –40°C to +105°C 4 µA (max)
V
MUTE
= V
DD
, C-Coupled
I
M
Mute Current T
A
= +25°C 50 100 50 100 µA (max)
T
A
= –40°C to +105°C 125 µA (max)
Shutdown Voltage Input
V
SDIH
T
A
= –40°C to +105°C 1.8 1.8 V
High
Shutdown Voltage Input
V
SDIL
T
A
= –40°C to +105°C 0.4 0.4 V
Low
V
MIH
Mute Voltage Input High T
A
= –40°C to +105°C 1.8 1.8 V
V
MIL
Mute Voltage Input Low T
A
= –40°C to +105°C 0.4 0.4 V
THD 1%, `C-CUPL, R
L
= 16
P
O
Output Power T
A
= +25°C 60 55 60 55 mW (min)
T
A
= –40°C to +105°C 50 mW (min)
Total Harmonic Distortion +
THD+N P
O
= 15.3mW, f = 1kHz 0.1 0.5 0.1 0.5 % (max)
(6)
Noise
Power Supply Rejection V
RIPPLE
= 200mV sine p-p
PSRR 65 65 dB
Ratio f = 1kHz
(7)
V
ON
Output Noise Voltage BW = 20Hz to 20kHz, A-weighted 10 10 µV
(1) All voltages are measured with respect to the GND pin unless otherwise specified.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional but do not ensure specific performance limits.Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which ensures specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not ensured for parameters where no limit is given; however, the typical value is a good indication
of device performance.
(3) Datasheet min/max specification limits are specified by design, test, or statistical analysis.
(4) Typicals are measured at 25°C and represent the parametric norm.
(5) Limits are specified to TI's AOQL (Average Outgoing Quality Level).
(6) The limit is specified over the temperature range of –40°C to +85°C.
(7) 10 terminated input.
Copyright © 2004–2011, Texas Instruments Incorporated Submit Documentation Feedback 5