Datasheet
LM4765
SNAS030C –AUGUST 1998–REVISED APRIL 2013
www.ti.com
CONNECTION DIAGRAM
Figure 2. Plastic Package - Top View
Non-Isolated Package
See Package Number NDL0015A
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ABSOLUTE MAXIMUM RATINGS
(1)(2)(3)
Supply Voltage |V
CC
| + |V
EE
| (No Input) 66V
Supply Voltage |V
CC
| + |V
EE
| (with Input) 64V
Common Mode Input Voltage (V
CC
or V
EE
) and |V
CC
| + |V
EE
| ≤ 60V
Differential Input Voltage 60V
Output Current Internally Limited
Power Dissipation
(4)
62.5W
ESD Susceptability
(5)
2000V
Junction Temperature
(6)
150°C
Thermal Resistance Non-Isolated NDL-Package θ
JC
1°C/W
Soldering Information NDL Package (10 sec.) 260°C
Storage Temperature −40°C to +150°C
(1) All voltages are measured with respect to the GND pins (5, 10), unless otherwise specified.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which ensure specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not ensured for parameters where no limit is given, however, the typical value is a good indication
of device performance.
(3) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(4) For operating at case temperatures above 25°C, the device must be derated based on a 150°C maximum junction temperature and a
thermal resistance of θ
JC
= 1°C/W for the NDL package. Refer to the section DETERMINING THE CORRECT HEAT SINK.
(5) Human body model, 100 pF discharged through a 1.5 kΩ resistor.
(6) The operating junction temperature maximum is 150°C, however, the instantaneous Safe Operating Area temperature is 250°C.
OPERATING RATINGS
(1)(2)
Temperature Range T
MIN
≤ T
A
≤ T
MAX
−20°C ≤ T
A
≤ +85°C
Supply Voltage |V
CC
| + |V
EE
|
(3)
20V to 64V
(1) All voltages are measured with respect to the GND pins (5, 10), unless otherwise specified.
(2) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is functional, but do not ensure specific performance limits. Electrical Characteristics state DC and AC electrical
specifications under particular test conditions which ensure specific performance limits. This assumes that the device is within the
Operating Ratings. Specifications are not ensured for parameters where no limit is given, however, the typical value is a good indication
of device performance.
(3) Operation is ensured up to 64V, however, distortion may be introduced from SPiKe Protection Circuitry if proper thermal considerations
are not taken into account. Refer to the APPLICATION INFORMATION section for a complete explanation.
2 Submit Documentation Feedback Copyright © 1998–2013, Texas Instruments Incorporated
Product Folder Links: LM4765