Datasheet

DescriptionResetTypeNameBit/Field
Trigger for Counter=Comparator B Up
DescriptionValue
An ADC trigger pulse is output when the counter matches the
value in the PWMnCMPB register value while counting up.
1
No ADC trigger is output.0
0R/WTrCmpBU12
Trigger for Counter=Comparator A Down
DescriptionValue
An ADC trigger pulse is output when the counter matches the
value in the PWMnCMPA register value while counting down.
1
No ADC trigger is output.0
0R/WTrCmpAD11
Trigger for Counter=Comparator A Up
DescriptionValue
An ADC trigger pulse is output when the counter matches the
value in the PWMnCMPA register value while counting up.
1
No ADC trigger is output.0
0R/WTrCmpAU10
Trigger for Counter=Load
DescriptionValue
An ADC trigger pulse is output when the counter matches the
PWMnLOAD register.
1
No ADC trigger is output.0
0R/WTrCntLoad9
Trigger for Counter=0
DescriptionValue
An ADC trigger pulse is output when the counter is 0.1
No ADC trigger is output.0
0R/WTrCntZero8
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0ROreserved7:6
Interrupt for Counter=Comparator B Down
DescriptionValue
A raw interrupt occurs when the counter matches the value in
the PWMnCMPB register value while counting down.
1
No interrupt.0
0R/WIntCmpBD5