Datasheet

Register 8: PWM Interrupt Status and Clear (PWMISC), offset 0x01C
This register provides a summary of the interrupt status of the individual PWM generator blocks. A
bit set to 1 indicates that the corresponding generator block is asserting an interrupt. The individual
interrupt status registers in each block must be consulted to determine the reason for the interrupt,
and used to clear the interrupt. For the fault interrupt, a write of 1 to that bit position clears the latched
interrupt status.
PWM Interrupt Status and Clear (PWMISC)
Base 0x4002.8000
Offset 0x01C
Type R/W1C, reset 0x0000.0000
16171819202122232425262728293031
IntFault
reserved
R/W1CROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
IntPWM0IntPWM1IntPWM2reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x00ROreserved31:17
Fault Interrupt Asserted
Indicates that the fault input is asserting an interrupt.
0R/W1CIntFault16
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x00ROreserved15:3
PWM2 Interrupt Status
Indicates if the PWM generator 2 block is asserting an interrupt.
0ROIntPWM22
PWM1 Interrupt Status
Indicates if the PWM generator 1 block is asserting an interrupt.
0ROIntPWM11
PWM0 Interrupt Status
Indicates if the PWM generator 0 block is asserting an interrupt.
0ROIntPWM00
June 18, 2012676
Texas Instruments-Production Data
Pulse Width Modulator (PWM)
NRND: Not recommended for new designs.