Datasheet

Register 5: PWM Output Fault (PWMFAULT), offset 0x010
This register controls the behavior of the PWM outputs in the presence of fault conditions. Both the
fault inputs and debug events are considered fault conditions. On a fault condition, each PWM signal
can be passed through unmodified or driven Low. For outputs that are configured for pass-through,
the debug event handling on the corresponding PWM generator also determines if the PWM signal
continues to be generated.
Fault condition control occurs before the output inverter, so PWM signals driven Low on fault are
inverted if the channel is configured for inversion (therefore, the pin is driven High on a fault condition).
PWM Output Fault (PWMFAULT)
Base 0x4002.8000
Offset 0x010
Type R/W, reset 0x0000.0000
16171819202122232425262728293031
reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
Fault0Fault1Fault2Fault3Fault4Fault5reserved
R/WR/WR/WR/WR/WR/WROROROROROROROROROROType
0000000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x00ROreserved31:6
PWM5 Fault
When set, the PWM5 output signal is driven Low on a fault condition.
0R/WFault55
PWM4 Fault
When set, the PWM4 output signal is driven Low on a fault condition.
0R/WFault44
PWM3 Fault
When set, the PWM3 output signal is driven Low on a fault condition.
0R/WFault33
PWM2 Fault
When set, the PWM2 output signal is driven Low on a fault condition.
0R/WFault22
PWM1 Fault
When set, the PWM1 output signal is driven Low on a fault condition.
0R/WFault11
PWM0 Fault
When set, the PWM0 output signal is driven Low on a fault condition.
0R/WFault00
673June 18, 2012
Texas Instruments-Production Data
Stellaris
®
LM3S8962 Microcontroller
NRND: Not recommended for new designs.