Datasheet

Register 20: SSI PrimeCell Identification 2 (SSIPCellID2), offset 0xFF8
The SSIPCellIDn registers are hard-coded, and the fields within the register determine the reset
value.
SSI PrimeCell Identification 2 (SSIPCellID2)
SSI0 base: 0x4000.8000
Offset 0xFF8
Type RO, reset 0x0000.0005
16171819202122232425262728293031
reserved
ROROROROROROROROROROROROROROROROType
0000000000000000Reset
0123456789101112131415
CID2reserved
ROROROROROROROROROROROROROROROROType
1010000000000000Reset
DescriptionResetTypeNameBit/Field
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x00ROreserved31:8
SSI PrimeCell ID Register [23:16]
Provides software a standard cross-peripheral identification system.
0x05ROCID27:0
June 18, 2012512
Texas Instruments-Production Data
Synchronous Serial Interface (SSI)
NRND: Not recommended for new designs.