Datasheet

DescriptionResetTypeNameBit/Field
SS1 Trigger Select
This field selects the trigger source for Sample Sequencer 1.
The valid configurations for this field are:
EventValue
Controller (default)0x0
Analog Comparator 00x1
Reserved0x2
Reserved0x3
External (GPIO PB4)0x4
Timer
In addition, the trigger must be enabled with the TnOTE bit in
the GPTMCTL register (see page 354).
0x5
PWM0
The PWM module 0 trigger can be configured with the PWM0
Interrupt and Trigger Enable (PWM0INTEN) register, see
page 680.
0x6
PWM1
The PWM module 1 trigger can be configured with the
PWM1INTEN register, see page 680.
0x7
PWM2
The PWM module 2 trigger can be configured with the
PWM2INTEN register, see page 680.
0x8
reserved0x9-0xE
Always (continuously sample)0xF
0x0R/WEM17:4
June 18, 2012414
Texas Instruments-Production Data
Analog-to-Digital Converter (ADC)
NRND: Not recommended for new designs.