Datasheet

2. A cold POR, when both the V
DD
and V
BAT
supplies are removed.
Any other reset condition is ignored by the Hibernation module.
Table 6-3. Hibernation Module Register Map
See
page
DescriptionResetTypeNameOffset
251Hibernation RTC Counter0x0000.0000ROHIBRTCC0x000
252Hibernation RTC Match 00xFFFF.FFFFR/WHIBRTCM00x004
253Hibernation RTC Match 10xFFFF.FFFFR/WHIBRTCM10x008
254Hibernation RTC Load0xFFFF.FFFFR/WHIBRTCLD0x00C
255Hibernation Control0x8000.0000R/WHIBCTL0x010
257Hibernation Interrupt Mask0x0000.0000R/WHIBIM0x014
258Hibernation Raw Interrupt Status0x0000.0000ROHIBRIS0x018
259Hibernation Masked Interrupt Status0x0000.0000ROHIBMIS0x01C
260Hibernation Interrupt Clear0x0000.0000R/W1CHIBIC0x020
261Hibernation RTC Trim0x0000.7FFFR/WHIBRTCT0x024
262Hibernation Data-R/WHIBDATA
0x030-
0x12C
6.6 Register Descriptions
The remainder of this section lists and describes the Hibernation module registers, in numerical
order by address offset.
June 18, 2012250
Texas Instruments-Production Data
Hibernation Module
NRND: Not recommended for new designs.