Datasheet

LM2900, LM3900
QUADRUPLE NORTON OPERATIONAL AMPLIFIERS
SLOS059 – JULY 1979 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM2900 LM3900 UNIT
Supply voltage, V
CC
(see Note 1) 36 36 V
Input current 20 20 mA
Duration of output short circuit (one amplifier) to ground at (or below) 25°C free-air temperature
(see Note 2)
unlimited unlimited
Continuous total dissipation See Dissipation Rating Table
Operating free-air temperature range 40 to 85 0 to 70 °C
Storage temperature range 65 to 150 65 to 150 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260 260 °C
NOTES: 1. All voltage values, except differential voltages, are with respect to the network ground terminal.
2. Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
DISSIPATION RATING TABLE
PACKAGE
T
A
25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
N 1150 mW 9.2 mW/°C 736 mW 598 mW
recommended operating conditions
LM2900 LM3900
UNIT
MIN MAX MIN MAX
UNIT
Supply voltage, V
CC
(single supply) 4.5 32 4.5 32 V
Supply voltage, V
CC+
(dual supply) 2.2 16 2.2 16 V
Supply voltage, V
CC
(dual supply) 2.2 –16 2.2 –16 V
Input current (see Note 3) –1 –1 mA
Operating free-air temperature, T
A
–40 85 0 70 °C
NOTE 3: Clamp transistors are included that prevent the input voltages from swinging below ground more than approximately –0.3 V. The
negative input currents that may result from large signal overdrive with capacitive input coupling must be limited externally to values
of approximately –1 mA. Negative input currents in excess of –4 mA causes the output voltage to drop to a low voltage. These
values apply for any one of the input terminals. If more than one of the input terminals are simultaneously driven negative, maximum
currents are reduced. Common-mode current biasing can be used to prevent negative input voltages.