Absolute Maximum Ratings
(1) (2)
VCC 0.3V to +6.0V
EN, FLAG1, FLAG2, FLAG3 0.3V to 6.0V
Max Flag 'ON' Current 50 mA
Storage Temperature Range 65°C to +150°C
Junction Temperature 150°C
Lead Temperature (Soldering, 5 sec.) 260°C
Minimum ESD Rating ±2 kV
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but does not ensure specific performance limits. For ensured specifications and conditions,
see the Electrical Characteristics.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
Operating Ratings
(1)
VCC to GND 2.7V to 5.5V
EN, FLAG1, FLAG2, FLAG3 0.3V to V
CC
+ 0.3V
Junction Temperature 40°C to +125°C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but does not ensure specific performance limits. For ensured specifications and conditions,
see the Electrical Characteristics.
Electrical Characteristics
Specifications with standard typeface are for T
J
= 25°C, and those in bold face type apply over the full Operating Temperature
Range (T
J
= -40°C to +125°C). Minimum and Maximum limits are specified through test, design or statistical correlation.
Typical values represent the most likely parametric norm at T
J
= 25°C and are provided for reference purposes only. V
CC
=
3.3V, and limits apply to all timing options, unless otherwise specified.
Symbol Parameter Conditions Min Typ Max Unit
(1) (2) (1)
I
Q
Operating Quiescent current 25 80 µA
Open Drain Flags
I
FLAG
FLAGx Leakage Current V
FLAGx
= 3.3V 1 20 nA
V
OL
FLAGx Output Voltage Low I
FLAGx
= 1.2mA 0.4 V
Power Up Sequence
t
d1
Timer delay 1 accuracy -15 15 %
2ms Timing Option -20 20
t
d2
Timer delay 2 accuracy -15 15 %
2ms Timing Option -20 20
t
d3
Timer delay 3 accuracy -15 15 %
2ms Timing Option -20 20
Power Down Sequence
t
d4
Timer delay 4 accuracy -15 15 %
2ms Timing Option -20 20
t
d5
Timer delay 5 accuracy -15 15 %
2ms Timing Option -20 20
t
d6
Timer delay 6 accuracy -15 15 %
2ms Timing Option -20 20
(1) Limits are 100% production tested at 25°. Limits over the operating temperature range are ensured through correlation using Statistical