5 Test Setup
5.1 Test Equipment
Voltage Source: 180 V
RMS
to 270 V
RMS
isolated AC source Agilent 6812B
Multimeters: Agilent 34410A
Power Meter: WT210 Digital Power Meter (Voltech)
Output Load: 10 LEDs in series (VF = 3.2 V at 350 mA per LED)
Oscilloscope: DPO4054 (TEKTRONIX)
Operating Temperature: 25°C
Recommended Wire Gauge: 18 AWG not more than two feet long
5.2 Recommended Test Setup
Figure 2. LM3447-PAR-230VEVM Recommended Test Set Up
5.3 List of Test Points
Table 2. Test Points Functions
TEST POINTS NAME DESCRIPTION
J3-1 Line 230 V
AC
neutral connection
J3-2 Neutral 230 V
AC
line voltage
LED+ LED anode connection
LED- LED cathode connection