Datasheet

Test Setup
www.ti.com
5 Test Setup
5.1 Test Equipment
Voltage Source: 190 V
RMS
to 265 V
RMS
isolated AC source PCR500LA (KIKUSUI)
Multimeters: Agilent 34401A
Power Meter: PM1000 Digital Power Meter (Voltech)
Output Load: 9 LEDs in series (VF = 3.2 V at 350 mA per LED)
Oscilloscope: TDS3045C (TEKTRONIX)
Operating Temperature: 25°C
Recommended Wire Gauge: 18 AWG not more than two feet long
5.2 Recommended Test Setup
Figure 2. LM3447-A19-230VEVM Recommended Test Set Up
5.3 List of Test Points
Table 2. Test Points Functions
TEST POINTS NAME DESCRIPTION
TP1 Neutral 230 V
AC
neutral connection
TP2 Line 230 V
AC
line voltage
J8 LED+ LED anode connection
J9 LED- LED cathode connection
6
LM3447-A19-230VEVM is a Phase-Dimmable, Primary-Side Regulated LED SLUU978June 2012
Driver
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated