Datasheet
LM3424
www.ti.com
SNVS603B –AUGUST 2009–REVISED OCTOBER 2009
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ABSOLUTE MAXIMUM RATINGS
(1)(2)
V
IN
, EN, nDIM -0.3V to 76.0V
-1 mA continuous
OVP, HSP, HSN -0.3V to 76.0V
-100 µA continuous
IS -0.3V to 76.0V
-2V for 100 ns
-1 mA continuous
V
CC
-0.3V to 8.0V
V
S
, TREF, TSENSE, TGAIN, COMP, CSH, RT, SLOPE, SS -0.3V to 6.0V
SS -30 µA to +30 µA continuous
GATE, DDRV -0.3V to V
CC
-2.5V for 100 ns
V
CC
+2.5V for 100 ns
-1 mA to +1 mA continuous
GND -0.3V to 0.3V
-2.5V to 2.5V for 100 ns
Maximum Junction Temperature Internally Limited
Storage Temperature Range −65°C to +150°C
Maximum Lead Temperature (Reflow and Solder)
(3)
260°C
Continuous Power Dissipation Internally Limited
ESD Susceptibility
(4)
Human Body Model 2 kV
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Operating Ratings is not implied. The recommended Operating Ratings indicate
conditions at which the device is functional and the device should not be operated beyond such conditions. All voltages are with respect
to the potential at the GND pin, unless otherwise specified.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3) Refer to TI’s packaging website for more detailed information and mounting techniques, http://www.ti.com/packaging.
(4) Human Body Model, applicable std. JESD22-A114-C.
OPERATING CONDITIONS
(1)
Operating Junction Temperature Range −40°C to +125°C
Input Voltage V
IN
4.5V to 75V
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Operating Ratings is not implied. The recommended Operating Ratings indicate
conditions at which the device is functional and the device should not be operated beyond such conditions. All voltages are with respect
to the potential at the GND pin, unless otherwise specified.
Copyright © 2009, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: LM3424