Datasheet
LM136-5.0, LM236-5.0, LM336-5.0
www.ti.com
SNVS750D –JUNE 1999–REVISED MARCH 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ABSOLUTE MAXIMUM RATINGS
(1)
Reverse Current 15 mA
Forward Current 10 mA
Storage Temperature −60 to +150 °C
Operating Temperature Range
(2)
LM136-5.0 −55 to +150 °C
LM236-5.0 −25 to +85 °C
LM336-5.0 0 to +70 °C
Soldering Information
TO-92 Package (10 sec.) 260 °C
TO Package (10 sec.) 300 °C
SOIC Package
Vapor Phase (60 sec.) 215 °C
Infrared (15 sec.) 220 °C
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Electrical specifications do not apply when
operating the device beyond its specified operating conditions.
(2) For elevated temperature operation, T
j
max see THERMAL CHARACTERISTICS
THERMAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted)
LM136 150°C
LM236 125°C
LM336 100°C
Thermal Resistance TO-92 TO SOIC-8
θ
ja
(Junction to Ambient) 180°C/W (0.4″ Leads) 440°C/W 165°C/W
170°C/W (0.125″ Leads)
θ
ja
(Junction to Case) N/A 80°C/W N/A
ELECTRICAL CHARACTERISTICS
LM136A-5.0/LM236A-5.0 LM336B-5.0
Parameter Conditions LM136-5.0/LM236-5.0 LM336-5.0 Units
Min Typ Max Min Typ Max
Reverse Breakdown T
A
=25°C, I
R
=1 mA
Voltage
LM136-5.0/LM236-5.0/LM336-5.0 4.9 5.00 5.1 4.8 5.00 5.2 V
LM136A-5.0/LM236A-5.0, LM336B-5.0 4.95 5.00 5.05 4.90 5.00 5.1 V
Reverse Breakdown T
A
=25°C, 6 12 6 20 mV
Change
With Current 600 μA≤I
R
≤10 mA
Reverse Dynamic T
A
=25°C, I
R
=1 mA, f = 100 Hz 0.6 1.2 0.6 2 Ω
Impedance
Temperature Stability V
R
Adjusted 5.00V
(2)
I
R
=1 mA, (Figure 15)
0°C≤T
A
≤70°C (LM336-5.0) 4 12 mV
(1) Unless otherwise specified, the LM136-5.0 is specified from −55°C≤T
A
≤+125°C, the LM236-5.0 from −25°C≤T
A
≤+85°C and the LM336-
5.0 from 0°C≤T
A
≤+70°C.
(2) Temperature stability for the LM336 and LM236 family is specified by design. Design limits are specified (but not 100% percent
production tested) over the indicated temperature and supply voltage ranges. These limits are not used to calculate outgoing quality
levels. Stability is defined as the maximum charge in V
REF
from 25°C to T
A
(min) or T
A
(max).
Copyright © 1999–2013, Texas Instruments Incorporated Submit Documentation Feedback 3