Absolute Maximum Ratings
(1)(2)
Input Voltage 26V to +0.3V
ESD Susceptibility
(3)
2 kV
Power Dissipation
(4)
Internally Limited
Junction Temperature (T
Jmax
) 125°C
Storage Temperature 65°C to +150°C
TO-220 (T), Wave 260°C, 10 sec
Soldering Temperature
DDPAK/TO-263 (S) 235°C, 30 sec
(1) Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but do not ensure specific performance limits. For ensured specifications and test
conditions, see the Electrical Characteristics.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3) Human body model, 100 pF discharged through a 1.5 kΩ resistor.
(4) The maximum power dissipation is a function of T
Jmax
, θ
JA
, and T
A
. The maximum allowable power dissipation at any ambient
temperature is P
D
= (T
Jmax
T
A
)/θ
JA
. If this dissipation is exceeded, the die temperature will rise above 125°C, and the LM2990 will
eventually go into thermal shutdown at a T
J
of approximately 160°C. For the LM2990, the junction-to-ambient thermal resistance, is
53°C/W, 73°C/W for the DDPAK/TO-263, and the junction-to-case thermal resistance is 3°C. If the DD[AK/TO-263 package is used, the
thermal resistance can be reduced by increasing the P.C. board copper area thermally connected to the package. Using 0.5 square
inches of copper area, θ
JA
is 50°C/W; with 1 square inch of copper area, θ
JA
is 37°C/W; and with 1.6 or more square inches of copper
area, θ
JA
is 32°C/W.
2 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated
Product Folder Links: LM2990